Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Journal of Biomedical Engineering ; (6): 61-70, 2020.
Article in Chinese | WPRIM | ID: wpr-788895

ABSTRACT

In order to quantitatively analyze the morphology and period of pulse signals, a time-space analytical modeling and quantitative analysis method for pulse signals were proposed. Firstly, according to the production mechanism of the pulse signal, the pulse space-time analytical model was built after integrating the period and baseline of pulse signal into the analytical model, and the model mathematical expression and its 12 parameters were obtained for pulse wave quantification. Then, the model parameters estimation process based on the actual pulse signal was presented, and the optimization method, constraints and boundary conditions in parameter estimation were given. The spatial-temporal analytical modeling method was applied to the pulse waves of healthy subjects from the international standard physiological signal sub-database Fantasia of the PhysioNet in open-source, and we derived some changes in heartbeat rhythm and hemodynamic generated by aging and gender difference from the analytical models. The model parameters were employed as the input of some machine learning methods, e.g. random forest and probabilistic neural network, to classify the pulse waves by age and gender, and the results showed that random forest has the best classification performance with Kappa coefficients over 98%. Therefore, the space-time analytical modeling method proposed in this study can effectively quantify and analyze the pulse signal, which provides a theoretical basis and technical framework for some related applications based on pulse signals.

2.
Chinese Journal of Medical Instrumentation ; (6): 5-9, 2016.
Article in Chinese | WPRIM | ID: wpr-265586

ABSTRACT

In order to improve the storage and transmission efficiency of dynamic photoplethysmography (PPG) signals in the detection process and reduce the redundancy of signals, the modified adaptive matching pursuit (MAMP) algorithm was proposed according to the sparsity of the PPG signal. The proposed algorithm which is based on reconstruction method of sparse adaptive matching pursuit (SAMP), could improve the accuracy of the sparsity estimation of signals by using both variable step size and the double threshold conditions. After experiments on the simulated and the actual PPG signals, the results show that the modified algorithm could estimate the sparsity of signals accurately and quickly, and had good anti-noise performance. Contrasting with SAMP and orthogonal matching pursuit (OMP), the reconstruction speed of the algorithm was faster and the accuracy was high.


Subject(s)
Humans , Algorithms , Image Processing, Computer-Assisted , Photoplethysmography
3.
Chinese Journal of Medical Instrumentation ; (6): 83-86, 2015.
Article in Chinese | WPRIM | ID: wpr-310268

ABSTRACT

In order to reduce the impact of various noise in pulse signal, the quality estimation and filtering algorithms based on cyclostationarity are proposed to reprocess pulse signal. First, A quality evaluation index of pulse signal which named quality factor is defined by cyclic spectrum to describe the quality variation of the pulse signal affected by noise; Second, a cyclic correlation matched filter (CCMF) is designed to remove noise. The simulation of pulse signal is produced by ourselves and noise signal is provided by MIT-BIH physiological database are used to test the function of proposed method, and then the method is applied to the actual pulse signal. The results show that the quality factor can accurately reflect the quality of the pulse signal and the CCMF can effectively remove noise from pulse signal.


Subject(s)
Humans , Algorithms , Databases, Factual , Heart Rate
4.
Chinese Journal of Medical Instrumentation ; (6): 235-239, 2015.
Article in Chinese | WPRIM | ID: wpr-265654

ABSTRACT

Pulse signal contains a wealth of biological and pathological information. However, it is susceptible to the influence of various factors which results in poor signal quality, and causes the device to generate false alarms. First the pulse signals are processing into discrete symbols, and then compare the test signal with the pulse template by using Dynamic Time Warping (DTW) to get the threshold for which can be used to find the interference segment of the test signal. By analyzing the DTW distance of the pulse signal, we can get the interference degree of the signal, then the quality level of the plus signal can be defined by the relationship between the interference degree and quality of the signal. The 1 055 group pulse signals provided by MIMIC II physiological database are used to train and test the signal quality assessment algorithms, and compared with other existing algorithms. The results show that the algorithms can accurately detect interference segments in pulse signal and reflect the quality of it.


Subject(s)
Humans , Algorithms , Heart Rate , Pulse , Signal Processing, Computer-Assisted
5.
Chinese Journal of Medical Instrumentation ; (6): 313-317, 2015.
Article in Chinese | WPRIM | ID: wpr-265632

ABSTRACT

In order to derive dynamic pulse rate variability (DPRV) signal from dynamic pulse signal in real time, a method for extracting DPRV signal was proposed and a portable mobile monitoring system was designed. The system consists of a front end for collecting and wireless sending pulse signal and a mobile terminal. The proposed method is employed to extract DPRV from dynamic pulse signal in mobile terminal, and the DPRV signal is analyzed both in the time domain and the frequency domain and also with non-linear method in real time. The results show that the proposed method can accurately derive DPRV signal in real time, the system can be used for processing and analyzing DPRV signal in real time.


Subject(s)
Electrocardiography , Heart Rate , Monitoring, Physiologic , Signal Processing, Computer-Assisted
6.
Chinese Journal of Medical Instrumentation ; (6): 79-84, 2012.
Article in Chinese | WPRIM | ID: wpr-325926

ABSTRACT

In order to obtain and process pulse signal in real-time, the integer coefficients notch, low-pass filters and an envelope filtering method were designed in consideration of the characteristics of disturbances in pulse signal and then were verified by MATLAB. The pulse signal was processed on DSP in time domain and frequency domain after simplifying the programming. The pulse wave height and pulse rate were calculated in real-time, and the pulse signal's spectrum was illustrated by FFT. The results show that the filters can effectively suppress the interference in pulse signal, and the system can detect and analyze the dynamic pulse signal in real-time.


Subject(s)
Algorithms , Equipment Design , Heart Rate , Signal Processing, Computer-Assisted , Software
SELECTION OF CITATIONS
SEARCH DETAIL